On a BIGTREETECH ViViD running MMS, use MMS_STATUS when filament stalls before the Gate. For a USB dropout, check the USB plugs and the path from the host to the ViViD and Buffer. For odd drying readings, check the two chamber sensors and the dryer’s heater target. BIGTREETECH ViViD manual, Klipper FAQ, MMS dryer configuration
If your ViViD runs Happy Hare, follow its ViViD setup guide.
Filament stalls before the Gate
After a failed feed, run MMS_STATUS in the Klipper console. Find the affected slot and read these three fields. The Gate sensor is at the Buffer inlet. ViViD fault detection
| Field | 0 | 1 |
|---|---|---|
selector | Slot is unselected | Slot is selected |
inlet | ViViD inlet switch is untriggered | Filament has triggered the ViViD inlet switch |
gate | Buffer inlet sensor is untriggered | Filament has triggered the Buffer inlet sensor |
- If
inletreads1andgatereads0after a failed feed, trace the PTFE tube from that ViViD slot to the matching Buffer port. Check that the clips hold the tube and that the bend radius is at least 60 mm along this run. MMS retries an Inlet-to-Gate feed when it exceeds the feed distance limit without triggering the Gate. ViViD tube routing, MMS configuration guide - To check the feed again using ViViD-adapted KlipperScreen, tap the affected slot and tap Pre-Load. Wait for the selector to finish homing and selecting the slot, then insert straight filament vertically into its inlet. ViViD preload instructions
USB drops out or Klipper cannot connect
If Klipper cannot connect at startup, run this over SSH on the Klipper host. MMS serial-ID instructions
ls /dev/serial/by-id/*
Match the full paths to the corresponding serial entries in config/bigtreetech-mms/mms/mms.cfg. The ViViD ID contains stm32g0b1xx_vivid and the Buffer ID contains stm32f042x6_buffer. If an ID is missing from the list, check the cable path below. ViViD serial configuration, MMS serial-ID instructions
If Klipper reports Lost communication with MCU after connecting, check that the USB plugs are secure and use a good-quality USB cable. Match your wiring to one of BIGTREETECH’s layouts. Klipper FAQ, ViViD connection diagrams
| Host USB connection | MX3.0 connection |
|---|---|
| Host to ViViD Input | ViViD Output to Buffer Input |
| Host to Buffer Input | Buffer Output to ViViD Input |
For hosts with USB driven directly by the system-on-chip, such as BTT Pi V1.2 or BTT Pi2, BIGTREETECH recommends the supplied USB hub. If the USB cable passes near stepper motors, the manual recommends ferrite cores on the motor cables near their controller board connections. ViViD USB signal guidance
Dryer readings or heating look wrong
In Mainsail, check the target for ViViD Heater. The supplied MMS configuration defines ViViD_Dryer_L and ViViD_Dryer_R as AHT3X sensors. It uses the higher of their two temperature readings for heater control. ViViD chamber heating, MMS dryer configuration
| Symptom | What to check |
|---|---|
| A reading is missing or looks wrong | Compare the left and right readings in Mainsail’s temperature panel and check the sensor names against bigtreetech-mms/hardware/mms-heater.cfg. Mainsail v2.16.0 added AHT3X support to the panel. MMS dryer configuration, Mainsail release notes |
| Drying fails to start after setting a target | Check for a SET_HEATER_TEMPERATURE override. BIGTREETECH documents a Voron bed-fan macro that can block the dryer target and shows how its fallback should pass the target to _SET_HEATER_TEMPERATURE. ViViD drying FAQ |
| Heating ends while the printer sits idle | Check timeout in [idle_timeout]. For a four-hour idle drying cycle, BIGTREETECH recommends timeout: 14400. Klipper’s default idle actions include turning off the heaters. ViViD chamber heating, Klipper idle timeout |
| Humidity stays high while heating | Open the chamber vents with the Humidity Exhaust Valve to let moisture out. ViViD chamber heating |
If a dryer reading stays missing or implausible, leave the dryer heater off and keep its temperature limits and heater verification enabled. Describe the affected reading and symptom when contacting support. BIGTREETECH technical support, Klipper heater verification
Evidence and limits. The BIGTREETECH ViViD wiki, MMS master configuration, Klipper documentation and Mainsail v2.16.0 release notes were checked on November 27, 2026. The steps were not run on hardware.